Reading Warmth, Not Just Leaks: A Pre-Winter Thermal Route for Hydraulic Power Units
Photo: West Midlands Ringing Group, CC BY-SA 4.0, via Wikimedia Commons
By the second week of November, many UK plants are already working against a familiar backdrop: shorter days, colder ambient air in unheated stores, and a production schedule that tightens before the Christmas shutdown. Hydraulic power units that have run comfortably through autumn are asked to hold pressure for longer shifts, often with less opportunity for planned intervention. A thermal camera is not a substitute for pressure testing, vibration analysis or oil sampling. Used properly, however, it is an efficient triage tool: a way of seeing where the power unit is working harder than it should before a minor restriction becomes a winter breakdown.
Why the pre-winter window matters
The argument for a thermographic walkaround is not that heat is always a fault. It is that heat distribution changes when a circuit stops behaving as designed. A return filter approaching bypass, a cooler thermostat stuck partly open or a coupling running out of alignment will each leave a different warm signature. In cold weather, those signatures can be masked by low oil temperatures, intermittent demand and the natural lag of a large reservoir. That is why the reading should be taken under a known, repeatable load rather than whenever an engineer happens to pass the unit.
A pre-winter campaign also establishes a baseline for the months ahead. If the same power unit is surveyed in November 2026 and again in January, the useful information is not a single absolute temperature but the change in pattern. A pump body that runs a few degrees warmer at the same duty, or a return line that has become hot close to the filter housing, tells a more reliable story than an isolated hot spot.
Set the camera before you set foot on the unit
Thermal surveys fail at the preparation stage more often than at the interpretation stage. Check the camera's emissivity setting against the materials being inspected. Painted steel, lagging and plastic guards behave differently from bare metal, and a shiny coupling guard can reflect heat from an adjacent surface. Record the reflected temperature where the camera allows it, particularly in a plant room with warm pipework nearby.
Focus is equally important. An out-of-focus thermal image smears temperature across edges and makes a small coupling fault look like a broad warm patch. Use a camera with a suitable spatial resolution for the components being checked, or keep enough distance to avoid filling the frame with a single unrepresentative surface. For routine surveys, a simple manual focus and a fixed colour palette are more useful than automatic settings that change between visits.
Before starting, note the operating condition. Record ambient temperature, oil temperature from the unit's gauge or sensor, approximate load, and how long the unit has been running. A power unit that has just started will not show a stable cooler pattern. A unit that has been idling for an hour may show a warm pump but a cool return line simply because there has been little flow through the circuit.
A repeatable route around the power unit
The value of a walkaround comes from doing it in the same order each time. Start at the reservoir and work outward through the flow path. This reduces the chance of missing a component and makes the resulting images easier to compare with previous surveys.
Reservoir and suction line
Look for uneven warmth across the reservoir shell. A broad, gentle temperature rise is normal after sustained running. A distinct warm band near a suction strainer or along a suction line can suggest restriction, but confirm it against the pump inlet vacuum rather than relying on the image alone. Check the breather area for warmth or condensation patterns; a damp breather is not a thermal fault in itself, but it can explain emulsion and changed oil behaviour.
Pump and drive coupling
Compare the pump body with the drive motor and with the same pump on a sister unit. A worn pump internal may show as a localised hot area, but the more reliable indicators are often a change in the temperature difference between inlet and outlet, or a pump that runs warmer at the same pressure and flow. Inspect the coupling guard carefully. Misalignment can produce a warm band on the guard or a temperature difference between coupling halves, but reflective guards and nearby hot surfaces are common false positives. Use the thermal image to decide where to place a vibration reading, not to condemn the coupling on its own.
Return filtration and cooler
This is where thermography earns its place in a pre-winter routine. A return filter approaching bypass often shows a warmer housing than expected for the flow and oil temperature, particularly downstream of the element. Compare the filter housing with the return line entering it and with the cooler outlet. A cooler that is bypassing may show a warm outlet when the thermostat should be sending oil through the cooler, or an unusually uniform cooler surface when part of the matrix is blocked.
Be cautious with cooler readings in cold weather. A thermostatic valve may be legitimately bypassing until the oil reaches operating temperature. Record the oil temperature at the time of the image and repeat the reading once the unit is warm. If the cooler remains cold while the return line is hot, that is a pattern worth investigating; if both are cold because the unit has only just started, the image has little diagnostic value.
Valves, accumulators and dead legs
Valve blocks and accumulator circuits can show local warmth from normal throttling. The useful comparison is between similar circuits or between the same circuit under the same duty. An accumulator that is warm in an unexpected area may indicate gas loss or internal leakage, but thermal imaging should be supported by precharge checks and pressure-decay tests. Dead legs and closed return lines may stay cool simply because there is no flow; do not interpret absence of heat as proof of health.
Establish baselines, not snapshots
A single thermal image is a record, not a diagnosis. The strongest use of the camera is trending. Keep the same camera settings, the same load condition and roughly the same ambient conditions where possible. If the plant cannot be held at a steady load, record what the unit was doing and treat the result as a screening reading rather than a baseline.
For each survey, capture an overview image of the power unit and close-ups of the pump, coupling guard, return filter housing, cooler inlet and outlet, and any component that has previously given trouble. Note the highest and lowest temperatures in each area, not just the apparent hot spot. A rise in the minimum temperature across a cooler can be as informative as a rise at a single point.
Common false positives
Thermal surveys attract scepticism when a warm image leads to an unnecessary strip-down. Frequent causes include solar gain through roof lights, hot air discharged from adjacent equipment, reflective stainless guards, recent oil top-ups, and units that have been running at low load. A camera that is not focused, or a palette that changes between visits, can also make normal variation look dramatic. Always ask whether the pattern follows the hydraulic flow path. If the warmth does not move with the oil, it may be an environmental effect rather than a machine fault.
A simple record sheet
A concise record is more useful than a folder of unlabelled images. The following fields are enough for most UK maintenance teams to begin trending:
| Field | Example entry |
|---|---|
| Date and time | 11 November 2026, 09:40 |
| Ambient and oil temperature | 11°C ambient; 42°C oil |
| Operating condition | 70% load, steady for 40 minutes |
| Camera settings | Emissivity 0.95, manual focus, fixed palette |
| Component | Return filter housing |
| Expected pattern | Warm but similar to return line |
| Observed temperature | 58°C maximum |
| Comparison | Sister unit 49°C at same duty |
| Action | Recheck in two weeks; inspect element at next service |
The action column matters. A thermal walkaround should end with a small number of clear decisions: monitor, investigate with another technique, or schedule work. It should not end with a list of warm surfaces and no priority.
A winter habit, not a one-off
A thermal camera is most valuable when it becomes part of the maintenance calendar rather than a specialist exercise. A repeatable route, a known load condition and a simple record sheet will reveal more than an occasional scan with the latest camera. Before the winter peak load arrives, give the power unit a defined thermal baseline. The images will not replace sound engineering judgement, but they will show where to apply it first.